flange
Application: water, liquids, gases, liquid and vapor.
Model: 100-D
Material: Steel A 105 N
pressure range which: PN 100 / ANSI 600 lbs
temperature: 400 ° C; steam 219ºC / 22 bar
Reflective Glass: Borosilicate Type B
Glass Seals: Graphite PSM / Klingersil
U-clamp ASTM 193-B7
nuts: ASTM 194-2H
Shut-off valves: Type D, Steel A105 (FS / H)
Connection:
Flanges PN 40
Options: View separate data sheet for afspærrringshane type D
Options:
- other connections.
- shows in combination with other isolation taps.
- stainless steel.
When ordering, specify:
- Media, pressure and temperature.
- Flange and center distance.
- Special valve functions.
- Desired documentation.
GENERALLY | DIMENSIONER (mm) | ||
---|---|---|---|
Item no. | Description | DN | flange |
25331015 | Top male D | 15 | 95 |
25331020 | Top male D | 20 | 105 |
25331025 | Top male D | 25 | 115 |
25331115 | Lower male D + blow off. male ABL 12 | 15 | 95 |
25331120 | Lower male D + blow off. male ABL 12 | 20 | 105 |
25331125 | Lower male D + blow off. ABL 12 | 25 | 115 |
25391012 | Exhaust valve ABL 12 PN160 | - | - |
DIMENSIONER (mm) | CENTERAFST.(mm) | ||||
---|---|---|---|---|---|
Item no. | Size (number of glass) | Sight Length | Showing Length | glass Length | Minimum |
35307212 | 1 x 2 | 118 | 153 | 140 | 255 |
35307213 | 1 x 3 | 143 | 178 | 165 | 280 |
35307214 | 1 x 4 | 168 | 203 | 190 | 305 |
35307215 | 1 x 5 | 198 | 233 | 220 | 335 |
35307216 | 1 x 6 | 228 | 263 | 250 | 365 |
35307217 | 1 x 7 | 258 | 293 | 280 | 395 |
35307218 | 1 x 8 | 298 | 333 | 320 | 435 |
35307219 | 1 x 9 | 318 | 353 | 340 | 455 |
35307224 | 2 x 4 | 373 | 408 | 190 | 510 |
35307225 | 2 x 5 | 433 | 468 | 220 | 570 |
35307226 | 2 x 6 | 493 | 528 | 250 | 630 |
35307227 | 2 x 7 | 553 | 588 | 280 | 690 |
35307228 | 2 x 8 | 633 | 668 | 320 | 770 |
35307229 | 2 x 9 | 673 | 708 | 340 | 810 |
35307236 | 3 x 6 | 758 | 793 | 250 | 895 |
35307237 | 3 x 7 | 848 | 883 | 280 | 985 |
35307238 | 3 x 8 | 968 | 1003 | 320 | 1105 |
35307239 | 3 x 9 | 1028 | 1063 | 340 | 1165 |
35307247 | 4 x 7 | 1143 | 1178 | 280 | 1280 |
35307248 | 4 x 8 | 1303 | 1338 | 320 | 1440 |
35307249 | 4 x 9 | 1383 | 1418 | 340 | 1520 |
35307257 | 5 x 7 | 1438 | 1473 | 280 | 1575 |
35307258 | 5 x 8 | 1638 | 1673 | 320 | 1775 |
35307259 | 5 x 9 | 1738 | 1773 | 340 | 1875 |
35307268 | 6 x 8 | 1973 | 2008 | 320 | 2110 |
35307269 | 6 x 9 | 2093 | 2128 | 340 | 2230 |
35307278 | 7 x 8 | 2308 | 2343 | 320 | 2445 |
35307279 | 7 x 9 | 2448 | 2483 | 340 | 2585 |
Reading the liquid level in the gauge glass is performed by the naked eye, which is why it is important that the material is transparent, making the liquid level is visible. Reflex systems are based on reflecting light from a specially designed surface on the glass. In a gas or vapor phase, the light is 100% reflected off the prismatic grooves, whereas in the liquid phase, the light is absorbed, which to the eye will appear as a dark indication of the level.